938 resultados para Sensitivity of dot-Elisa


Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTR.4CT Senitivity of dot-immunobindinding ELf SA on nitrocellulose membrane (DotELISA)was compared with double-antibody sandwich ELISA (DAS-ELlSA) on polystyrene plates for the detection of bean yellow mosaic virus (BYMV), broad bean stain virus (WMV-2). Dot-ELISA was 2 and 1O times more sensitive than DAS-ELISA for the detection of BBSV and WMV-2, respectively, whereas DAS-ELISA was more sensitive than Dot-ELiSA for {he detection of BYMV. Both techniques were equally sensitive for the detection of BYDV. Using one day instead uf the two-day procedure, the four viruses were still detectable and the ralative sensitivity of both techniques remained the same.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alveolar echinococcosis (AE), caused by larva stage of Echinococcus multilocularis, is one of the lethal parasitic diseases of man and a major public health problem in many countries in the northern hemisphere. When the living conditions and habits in Turkey were considered in terms of relation with the life cycle of the parasite, it was suggested that AE has been much more common than reported mainly from the Eastern Anatolia region of Turkey. Since in vitro serologic diagnosis tests with high specificity for AE have not been used in our country, most of the cases with liver lesions were misdiagnosed by radiological investigations as malignancies. The aim of this study was to evaluate the diagnostic value of the in-house ELISA methods developed by using three different antigens (EgHF, Em2, EmII/3-10) in the serological diagnosis of AE. The study samples included a total of 100 sera provided by Bern University Parasitology Institute where samples were obtained from patients with helminthiasis and all were confirmed by clinical, parasitological and/or histopathological means. Ten samples from each of the cases infected by E.multilocularis, E.granulosus, Taenia solium, Wuchereria bancrofti, Strongyloides stercolaris, Ascaris lumbricoides, Toxocara canis, Trichinella spiralis, Fasciola hepatica and Schistosoma haematobium were studied. In the study, EgHF (E.granulosus hydatid fluid) antigens were prepared in our laboratory from the liver cyst fluids of sheeps with cystic echinococcosis, however Em2 (E.multilocularis metacestode-purified laminated layer) and EmII/3-10 (E.multilocularis recombinant protoscolex tegument) antigens were provided by Bern University Parasitology Institute. Flat bottom ELISA plates were covered with EgHF, Em2 and EmII/3-10 antigens in the concentrations of 2.5 µg, 1 µg and 0.18 µg per well, respectively, and all sera were tested by EgHF-ELISA, Em2-ELISA and EmII/3-10-ELISA methods. For each tests, the samples which were reactive above the cut-off value (mean OD of negative controls+2 SD) were accepted as positive. The sensitivity of the ELISA tests performed with EgHF, Em2 and Em2II/3-10 antigens were estimated as 100%, 90% and 90%, respectively, whereas the specificity were 63%, 91% and 91%, respectively. When Em2-ELISA and EmII/3-10-ELISA tests were evaluated together, the specificity increased to 96%. Our data indicated that the highest sensitivity (100% with EgHF-ELISA) and specificity (96% with Em2-ELISA + EmII/3-10-ELISA) for the serodiagnosis of AE can be achieved by the combined use of the ELISA tests with three different antigens. It was concluded that the early and accurate diagnosis of AE in our country which is endemic for that disease, could be supported by the use of highly specific serological tests such as Em2-ELISA ve EmII/3-10-ELISA contributing radiological data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dot enzyme-linked immunosorbent assay (dot-ELISA), indirect ELISA and Western blot were performed to detect the virulent protease secreted by Vibrio anguillarum which was isolated from the diseased left-eyed flounder, Paralichthys olivaceous. Sensitivity results showed that dot-ELISA is a more sensitive, rapid and simple technique for the protease detection. The minimal detectable amount of protease is about 7 pg in the dot-ELISA test, while 7.8 ng in the indirect ELISA and 6.25 ng in the Western blot respectively. Protease could be detected 2 h after incubation of V. anguillarum in the 2216E liquid medium but enzyme activity was very low at that period. From 6 to 12 h, the amount and enzyme activity of protease increased markedly and reached maximum at stationary phase. Analysis of serum samples periodically collected from the infected flounders showed that after 2 h of infection by V. anguillarum, the pathogenic bacteria could be detected in the blood of the infected flounders but no protease was found. It was 5 similar to 6 h after infection that the protease was detected in blood and then the amount increased as infection advanced. Quantitative detection of protease either incubation in the medium or from the blood of infected flounders could be accomplished in virtue of positive controls of quantificational protease standards ("marker") so that the alterations of protease secretion both in vitro and in vivo could be understood generally. In addition, the indirect ELISA and dot-ELISA were also performed to detect V. anguillarum cells. Results indicated that the sensitivity of indirect ELISA to bacteria cells is higher than that of the dot-ELISA, and that the minimal detectable amount is approximately 10(4) cell/mL in the indirect ELISA, while 10(5) cell/mL in the dot-ELISA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, the validation of an enzyme-linked immunosorbent assay (ELISA) for serodiagnosis of canine brucellosis is described. Two different antigenic extracts, obtained by heat or ultrasonic homogenization of microbial antigens from a wild isolate of Brucella canis bacteria, were compared by ELISA and Western blot (WB). A total of 145 canine sera were used to define sensitivity, specificity and accuracy of the ELISA as follows: (1) sera from 34 animals with natural B. canis infection, confirmed by blood culture and PCR, as well as 51 sera samples from healthy dogs with negative results by the agar-gel immunodiffusion (ACID) test for canine brucellosis, were used as the control panel for B. cants infection; and (2) to scrutinize the possibility of cross reactions with other common dog infections in the same geographical area in Brazil, 60 sera samples from dogs harboring known infections by Leptospira sp., Ehrlichia canis, canine distemper virus (CDV), Neospora caninum, Babesia canis and Leishmania chagasi (10 in each group) were included in the study. The ELISA using heat soluble bacterial extract (HE-antigen) as antigen showed the best values of sensitivity (91.18%), specificity (100%) and accuracy (96.47%). In the WB analyses, the HE-antigen showed no cross-reactivity with sera from dogs with different infections, while the B. canis sonicate had various protein bands identified by those sera. The performance of the ELISA standardized with the heat soluble B. canis antigen indicates that this assay can be used as a reliable and practical method to confirm infection by this microorganism, as well as a tool for seroepidemiological studies. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Um ensaio de imunoadsorção enzimática (ELISA) baseado em antígeno bruto foi avaliado na detecção de anticorpos contra Babesia bigemina. A sensibilidade e a especificidade do teste foram de 98,0% e 99,0%, respectivamente. Concordando com a alta especificidade do teste, não foram verificadas reações cruzadas com soros de bezerros inoculados três vezes com 10(7) merozoítos de Babesia bovis. Com relação à comparação do ELISA com a imunofluorescência indireta (IFAT) na detecção de anticorpos contra B. bigemina em bezerros experimentalmente infectados com cinco isolados brasileiros geograficamente distintos deste hemoparasito, o IFAT foi capaz de detectar anticorpos um dia antes do ELISA na maioria dos soros dos animais. Houve uma boa concordância entre os resultados encontrados no ELISA e no IFAT com soros de bovinos de região de estabilidade enzoótica (k=0.61). No entanto, não houve concordância entre os testes sorológicos com soros de animais de área de instabilidade enzoótica (k=0.33). O ELISA foi empregado em um inquérito epidemiológico com 1.367 soros de quatro municípios do Pantanal de Mato Grosso do Sul e caracterizou esta região como uma área de estabilidade enzoótica, uma vez que as prevalências variaram de 87,7 a 98,9%. Dessa forma, este ELISA, que apresentou alta sensibilidade, especificidade e desempenho similar ao IFAT, pode ser utilizado no diagnóstico sorológico de B. bigemina.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In 2010, a large outbreak of dengue occurred in Santos, Brazil. The detection of the NS1 antigen was used for diagnosis in addition to the detection of IgG, IgM, and RNA. A large number of NS1 false-negative results were obtained. A total of 379 RNA-positive samples were selected for thorough evaluation. NS1 was reactive in 37.7% of cases. Most of the cases were characterized as a secondary infection by dengue 2 virus. Sequencing of NS1 positive and negative isolates did not reveal any mutation that could justify the diagnostic failure. Use of existing NS1 tests in the Brazilian population may present a low negative predictive value, and they should be used with caution, preferentially after performing a validation with samples freshly obtained during the ongoing epidemic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue just as is common in echo ultrasound. We demonstrate in three-dimensional simulations, phantom experiments, and in vivo mouse experiments that for vascular imaging this interpretation is often inaccurate. The cylindrical blood vessels emit anisotropic acoustic transients, which can be sensitively detected only if the direction of acoustic radiation coincides with the probe aperture. Our results reveal for this reason that the signal amplitude of different blood vessels may differ even if the vessels have the same diameter and initial pressure distribution but different orientation relative to the imaging plane. This has important implications for the image interpretation, for the probe guidance technique, and especially in cases when a quantitative reconstruction of the optical tissue properties is required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Areal bone mineral density (aBMD) is the most common surrogate measurement for assessing the bone strength of the proximal femur associated with osteoporosis. Additional factors, however, contribute to the overall strength of the proximal femur, primarily the anatomical geometry. Finite element analysis (FEA) is an effective and widely used computerbased simulation technique for modeling mechanical loading of various engineering structures, providing predictions of displacement and induced stress distribution due to the applied load. FEA is therefore inherently dependent upon both density and anatomical geometry. FEA may be performed on both three-dimensional and two-dimensional models of the proximal femur derived from radiographic images, from which the mechanical stiffness may be redicted. It is examined whether the outcome measures of two-dimensional FEA, two-dimensional, finite element analysis of X-ray images (FEXI), and three-dimensional FEA computed stiffness of the proximal femur were more sensitive than aBMD to changes in trabecular bone density and femur geometry. It is assumed that if an outcome measure follows known trends with changes in density and geometric parameters, then an increased sensitivity will be indicative of an improved prediction of bone strength. All three outcome measures increased non-linearly with trabecular bone density, increased linearly with cortical shell thickness and neck width, decreased linearly with neck length, and were relatively insensitive to neck-shaft angle. For femoral head radius, aBMD was relatively insensitive, with two-dimensional FEXI and threedimensional FEA demonstrating a non-linear increase and decrease in sensitivity, respectively. For neck anteversion, aBMD decreased non-linearly, whereas both two-dimensional FEXI and three dimensional FEA demonstrated a parabolic-type relationship, with maximum stiffness achieved at an angle of approximately 15o. Multi-parameter analysis showed that all three outcome measures demonstrated their highest sensitivity to a change in cortical thickness. When changes in all input parameters were considered simultaneously, three and twodimensional FEA had statistically equal sensitivities (0.41±0.20 and 0.42±0.16 respectively, p = ns) that were significantly higher than the sensitivity of aBMD (0.24±0.07; p = 0.014 and 0.002 for three-dimensional and two-dimensional FEA respectively). This simulation study suggests that since mechanical integrity and FEA are inherently dependent upon anatomical geometry, FEXI stiffness, being derived from conventional two-dimensional radiographic images, may provide an improvement in the prediction of bone strength of the proximal femur than currently provided by aBMD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Lane Change Test (LCT) is one of the growing number of methods developed to quantify driving performance degradation brought about by the use of in-vehicle devices. Beyond its validity and reliability, for such a test to be of practical use, it must also be sensitive to the varied demands of individual tasks. The current study evaluated the ability of several recent LCT lateral control and event detection parameters to discriminate between visual-manual and cognitive surrogate In-Vehicle Information System tasks with different levels of demand. Twenty-seven participants (mean age 24.4 years) completed a PC version of the LCT while performing visual search and math problem solving tasks. A number of the lateral control metrics were found to be sensitive to task differences, but the event detection metrics were less able to discriminate between tasks. The mean deviation and lane excursion measures were able to distinguish between the visual and cognitive tasks, but were less sensitive to the different levels of task demand. The other LCT metrics examined were less sensitive to task differences. A major factor influencing the sensitivity of at least some of the LCT metrics could be the type of lane change instructions given to participants. The provision of clear and explicit lane change instructions and further refinement of its metrics will be essential for increasing the utility of the LCT as an evaluation tool.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The relationship between organic matter (OM) lability and temperature sensitivity is disputed, with recent observations suggesting that responses of relatively more resistant OM to increased temperature could be greater than, equivalent to, or less than responses of relatively more labile OM. This lack of clear understanding limits the ability to forecast carbon (C) cycle responses to temperature changes. Here, we derive a novel approach (denoted Q(10-q)) that accounts for changes in OM quality during decomposition and use it to analyze data from three independent sources. Results from new laboratory soil incubations (labile Q(10-q)=2.1 +/- 0.2; more resistant Q(10-q)=3.8 +/- 0.3) and reanalysis of data from other soil incubations reported in the literature (labile Q(10-q)=2.3; more resistant Q(10-q)=3.3) demonstrate that temperature sensitivity of soil OM decomposition increases with decreasing soil OM lability. Analysis of data from a cross-site, field litter bag decomposition study (labile Q(10-q)=3.3 +/- 0.2; resistant Q(10-q)=4.9 +/- 0.2) shows that litter OM follows the same pattern, with greater temperature sensitivity for more resistant litter OM. Furthermore, the initial response of cultivated soils, presumably containing less labile soil OM (Q(10-q)=2.4 +/- 0.3) was greater than that for undisturbed grassland soils (Q(10-q)=1.7 +/- 0.1). Soil C losses estimated using this approach will differ from previous estimates as a function of the magnitude of the temperature increase and the proportion of whole soil OM comprised of compounds sensitive to temperature over that temperature range. It is likely that increased temperature has already prompted release of significant amounts of C to the atmosphere as CO2. Our results indicate that future losses of litter and soil C may be even greater than previously supposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Deformation Behaviour of microcrystalline (mc) and nanocrystalline (nc) Mg-5%Al alloys produced by hot extrusion of ball-milled powders were investigated using instrumented indentation tests. The hardness values of the mc and nc metals exhibited indentation size effect (ISE), with nc alloys showing weaker ISE. The highly localized dislocation activities resulted in a small activation volume, hence enhanced strain rate sensitivity. Relative higher strain rate sensitivity and the negative Hall-Petch Relationship suggested the increasingly important role of grain boundary mediated mechanisms when the grain size decreased to nanometer region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the grain size dependence of mechanical properties and deformation mechanisms of microcrystalline (mc) and nanocrystalline (nc: grain size below 100 nm) Mg-5wt% Al alloys. The Hall-Petch relationship was investigated by both instrumented indentation tests and compression tests. The test results from the indentation tests and compression tests match well with each other. The breakdown of Hall-Petch relationship and the elevated strain rate sensitivity (SRS) of present Mg-5wt% Al alloys when the grain size was reduced below 58nm indicated the more significant role of GB mediated mechanisms in plastic deformation process. However, the relatively smaller SRS values compared to GB sliding and coble creep process suggested the plastic deformation in the current study is still dislocation mediated mechanism dominant.